Description: Life End Error Subject periodic replacement parts reached the end of the life.
Causes: • Periodic replacement parts reached the end of the life Parts/Components to be checked 1. Pump Cap Unit 2. Ink Holder 3. Ink Tube
Remedy: 1 Replace the life end parts • Replace the life end parts, and perform the counter reset using Service Program. Does the product recover from the error? Y: End N: Escalate to person in charge
Code: 001125
Description: CR HP Detection Error Could not detect the CR Unit touching the specified position when performing CR home position returning. (could not detect the home position)
Causes: • Misreading of CR Scale (scratch, dirt) • CR Encoder failure • CR Motor failure Parts/Components to be checked 1. CR Scale 2. CR Encoder 3. CR Motor
Remedy: 1 Check whether the CR Unit is unlocked • After turning the power on, check if the CR Unit is unlocked properly. If not, check the state of the Pump Cap Unit. If it is broken, replace it. Does the product recover from the error? Y: End N: Go to step 2 2 Check the CR Scale state • Check visually if the CR Scale have any scratches or dirt. ƒß When the CR Scale is dirty: clean it. ƒß When there is a scratch on the CR Scale: replace it. Does the product recover from the error? Y: End N: Go to step 3 3 Check the CR Motor operation state ƒß When the CR Motor is malfunctioning, replace it. Does the product recover from the error? Y: End N: Go to step 4 4 Replace the Encoder Board Does the product recover from the error? Y: End N: Escalate to person in charge
Code: 001128
Description: Cutter HP Detection Error Detected that the Cutter cannot return to the home position, or cannot move from the home position.
Remedy: 1 Check the Cutter Blade installation state • Check if the Cutter Blade is installed properly. If not, install it again. Does the product recover from the error? Y: End N: Go to step 2 2 Replace the Cutter Blade Does the product recover from the error? Y: End N: Go to step 3 3 Check the Cutter Assy cable connection • Check the Cutter Motor connection state. If there is any abnormality, connect it again. Does the product recover from the error? Y: End N: Go to step 4 4 Check the Cutter Sensor cable connection • Check the Cutter Sensor connection state. If there is any abnormality, connect it again. Does the product recover from the error? Y: End N: Go to step 5 5 Check the Cutter Sensor installation state • Check if the Cutter Sensor is installed properly. If not, install it again. • Does the product recover from the error? Y: End N: Go to step 6 6 Replace the Cutter Sensor Does the product recover from the error? Y: End N: Go to step 7 7 Replace the Cutter Assy Does the product recover from the error? Y: End N: Escalate to person in charge
Code: 001135
Description: CR Motor Cable Disconnection Error CR Motor did not operate when CR Motor cable disconnection check with power on.
Causes: • CR Motor failure • CR Motor cable abnormality (connection, broken) • Misreading of CR Scale (scratch, dirt) • CR Encoder failure • CR Sub Board failure Parts/Components to be checked 1. CR Motor 2. CR Scale 3. CR Encoder 4. CR Sub Board
Remedy: 1 Check the CR Motor cable connection • Check the CR Motor connection state. If there is any abnormality, connect it again. Does the product recover from the error? Y: End N: Go to step 2 2 Check the CR Motor operation state • When the CR Motor is malfunctioning, replace it. Does the product recover from the error? Y: End N: Go to step 3 3 Check the CR Scale state • Check visually if the CR Scale have any scratches or dirt. ƒß When the CR Scale is dirty: clean it. ƒß When there is a scratch on the CR Scale: replace it. Does the product recover from the error? Y: End N: Go to step 4 4 Check the Encoder Board and CR Sub Board cable connection • Check both Encoder Board and CR Sub Board connection state. If there is any abnormality, connect it again. Does the product recover from the error? Y: End N: Go to step 5 5 Replace the Encoder Board Does the product recover from the error? Y: End N: Go to step 6 6 Replace the CR Sub Board Does the product recover from the error? Y: End N: Escalate to person in charge
Code: 001136
Description: CR Movement Error (PG Lever Assy Interfere) APG Lever interfered when the carriage moved.
Causes: • APG Lever state abnormality • APG Lever failure • APG Flag failure Parts/Components to be checked 1. APG Lever 2. APG Flag
Remedy: 1 Check the APG Lever state • Check if the APG Lever is interfering the carriage when it is moving. If so, put back the APG Lever. Does the product recover from the error? Y: End N: Go to step 2 2 Check the damage of APG Lever • Replace the APG Lever when it is damaged. Does the product recover from the error? Y: End N: Go to step 3 3 Check the damage of APG Flag • Replace the APG Flag when it is damaged. Does the product recover from the error? Y: End N: Escalate to person in charge
Code: 001137
Description: CR Movement Prohibition Error Detected the APG Lever sticking out when about to move the CR Unit.
Causes: • APG Lever failure • APG Flag failure • F/W abnormality Parts/Components to be checked 1. APG Lever 2. APG Flag
Remedy: 1 Check the APG Lever installation state • Check if the APG Lever is installed properly. If not, install it again. Does the product recover from the error? Y: End N: Go to step 2 2 Replace the APG Lever Does the product recover from the error? Y: End N: Go to step 3 Replace the APG Flag Does the product recover from the error? Y: End N: Go to step 4 Update the F/W Does the product recover from the error? Y: End N: Escalate to person in charge