Description: Fixing Thermistor high temperature detection error. The Fixing Main Thermistor detected a high temperature error.
Causes: - Harness connecting the DC Controller PCB (J122), Drawer Unit (J5012) - Power Supply Unit - DC Controller PCB - Feed/Drum Driver PCB - Relay PCB - Fixing Motor (M21) - Fixing Film Unit - Pressure Roller Unit - Shutter Unit - Fixing Drive Unit - 27T Gear - Fixing Unit
Remedy: - Check COPIER> DISPLAY> ANALOG> FIX-E. a. In the case of below 283 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. In the case of 283 deg C or higher, check/replace the related harness/cable, connector and parts. [Caution] When replacing the Fixing Film Unit, turn the power ON after replacement. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.
Code: E001-0002-05
Description: Fixing Thermistor high temperature detection error. The Fixing Thermistor (Front) detected a high temperature error.
Causes: - Harness connecting the DC Controller PCB (J122), Drawer Unit (J5012) - Power Supply Unit - DC Controller PCB - Feed/Drum Driver PCB - Relay PCB - Fixing Motor (M21) - Fixing Film Unit - Pressure Roller Unit - Shutter Unit - Fixing Drive Unit - 27T Gear - Fixing Unit
Remedy: - Check COPIER> DISPLAY> ANALOG> FIX-E2. a. In the case of below 295 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. In the case of 295 deg C or higher, check/replace the related harness/cable, connector and parts. [Caution] When replacing the Fixing Film Unit, turn the power ON after replacement. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.
Code: E001-0003-05
Description: Fixing Thermistor high temperature detection error. The Fixing Thermistor (Rear) detected a high temperature error.
Causes: - Harness connecting the DC Controller PCB (J122), Drawer Unit (J5012) - Power Supply Unit - DC Controller PCB - Feed/Drum Driver PCB - Relay PCB - Fixing Motor (M21) - Fixing Film Unit - Pressure Roller Unit - Shutter Unit - Fixing Drive Unit - 27T Gear - Fixing Unit
Remedy: - Check COPIER> DISPLAY> ANALOG> FIX-E3. a. In the case of below 295 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. In the case of 295 deg C or higher, check/replace the related harness/cable, connector and parts. [Caution] When replacing the Fixing Film Unit, turn the power ON after replacement. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR
Code: E001-0011-05
Description: Fixing Thermistor high temperature detection error. The Fixing Film Unit Main Thermistor detected an abnormally high temperature.
Causes: - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Fixing Film Unit - Pickup Driver PCB (UN4)
Remedy: Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Main Thermistor. 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Code: E001-0012-05
Description: Fixing Thermistor high temperature detection error. The Fixing Film Unit Sub Thermistor 1 detected an abnormally high temperature.
Causes: - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003) - Fixing Film Unit - Pickup Driver PCB (UN4)
Remedy: Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Sub Thermistor 1. 2. Pull out the Fixing Feed Unit and check "FIX-UC2". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC2" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Code: E001-0013-05
Description: Fixing Thermistor high temperature detection error. The Fixing Film Unit Sub Thermistor 2 detected an abnormally high temperature.
Causes: - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003) - Fixing Film Unit - Pickup Driver PCB (UN4)
Remedy: Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Sub Thermistor 2. 2. Pull out the Fixing Feed Unit and check "FIX-UC3". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC3" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.