Description: Startup error
The temperature detected by the main or sub thermistor does not rise to the specified value during startup control.
Remedy: - Check the fixing film connector. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E001-0000
Description: Abnormally high temperature (detected by main thermistor)
The main thermistor detected an abnormally high temperature 235 deg C) during temperature control
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E001-0001
Description: Abnormally high temperature (detected by sub thermistor)
The sub thermistor detected an abnormally high temperature (300 deg C) during temperature control.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E002-0000
Description: Low temperature during temperature control.
The target temperature is not reached during temperature control.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E003-0000
Description: Abnormally low temperature (detected by main thermistor)
After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E003-0001
Description: Abnormally low temperature (detected by sub thermistor)
After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.