Description: System firmware / system software model information consistency error
Causes: Invalid system firmware / system software is installed.
Remedy: Setting 1. Confirm the model of the equipment. 2. Install the system firmware corresponding to the model. 3. Install the system software corresponding to the model. SYS board Replace the SYS board.
Code: F902_2
Description: A model-unmatched SYS board is installed or the SRAM is cleared
Causes: • The SYS board for e-STUDIO2010AC/2510AC is installed in 25/30/35/45/50 ppm. Or the opposite combination. • The SRAM is cleared.
Remedy: SYS board Check if the model of the equipment matches the part number of the SYS board. Setting Perform the following procedure if an error occurs when the SRAM is cleared. 1. Perform FS-08 SETTING MODE. 2. When “SRAM REQUIRES INITIALIZATION” is displayed on the display, check the destination and then press the [START] button. If the destination is not correct, key in the correct one and then press the [START] button. 3. After the confirmation message is displayed, press the [Initialize] button. (SRAM is initialized.) 4. Enter the serial number (FS-08-9601). Match it with the serial number on the label attached to the rear cover of the equipment. 5. Initialize the NIC information (FS-08-9083). 6. Perform 05 ADJUSTMENT MODE. 7. Perform “Data transfer of characteristic value of scanner” (FS-05-3203, FS-05-3240). 8. Perform “Automatic gamma adjustment” <PPC> (FS-05- 7869). 9. Perform “Automatic gamma adjustment” <PRT> (FS-05- 8008, FS-05-8009). 10.Turn the power OFF and then back ON.
Code: F902_3
Description: SRAM abnormality on the SYS board
Causes: SRAM abnormality on the SYS board
Remedy: SRAM 1. Check that the SRAM is installed properly. 2. Shut down the equipment. 3. Perform [FS-08]. 4. Press [CLASSIC]. 5. When “SRAM REQUIRES INITIALIZATION” appears on the LCD screen, confirm the destination and press the [START] button. If the destination is incorrect, enter the number for the correct one and press the [START] button. 6. When the confirmation message appears on the LCD screen, press [INITIALIZE]. (SRAM initialization starts.) 7. Enter the serial number of the equipment correctly. (FS-08- 9601) 8. Initialize the NIC information. (FS-08-9083) 9. Shut down the equipment. 10.Perform [FS-05]. 11.Press [CLASSIC]. 12.Perform “Data transfer of characteristic value of scanner”. (FS-05-3203, FS-05-3240) 13.By using the [4] [TEST PRINT] test pattern, perform “Automatic gamma adjustment” <PPC>. (FS-05-7869) 14.By using the [70] [TEST PRINT] test pattern, perform “Automatic gamma adjustment” <PRT>. (FS-05-8008, FS- 05-8009) 15.Reboot the equipment. 16.If the error still occurs, replace the SRAM. SYS board Board check
Code: F902_4
Description: SYS board model information consistency error
Causes: Invalid SYS board is installed to the equipment.
Remedy: SYS board Check if the model of the equipment matches the color of the label on the SYS board. Setting 1. Install the system firmware. 2. If the error cannot be solved after installing the system firmware, reinstall the system software and application program.