PrintCopy.info service

Toshiba e-Studio 232

Error Codes List page 25

  • Code: F110
  • Description: Communication error between System-CPU and Scanner- CPU
  • Remedy: (1) Check if the harness connecting the SYS board and SLG board is disconnected or open circuited. (2) Check the version of the system ROM on the SYS board. (3) Check the version of the scanner ROM version on the SLG board. (4) Replace the SYS board. (5) Replace the SLG board.
  • Code: F111
  • Description: Scanner response abnormality
  • Remedy: (1) Check if the harness connecting the SYS board and SLG board is disconnected or open circuited. (2) Check the version of the system ROM on the SYS board. (3) Check the version of the scanner ROM version on the SLG board. (4) Replace the SYS board. (5) Replace the SLG board.
  • Code: F130
  • Description: Invaid MAC addressData overwrite kit (GP-1050/1060) is taken off
  • Remedy: Compare the serial number of the equipment with a number displayed in 08-995. If they are different, enter the correct serial number at 08-995.
  • Code: F200
  • Description: Data overwrite kit (GP-1050/1060) is taken off
  • Remedy: Check the system ROM version (08-900) since the countermeasure to be taken varies. T377SY0*329 or later (* represents a letter of the alphabet corresponding to the destination.) Earlier than T377SY0*329 (* represents a letter of the alphabet corresponding to the destination.) Clear the service call “F200”. (Key in “0” at 08-633.) * When the Data overwrite kit (GP-1060) is removed from the equipment, the service call “F200” occurs.