Description: Communication error between System-CPU and Scanner- CPU
Remedy: (1) Check if the harness connecting the SYS board and SLG board is disconnected or open circuited. (2) Check the version of the system ROM on the SYS board. (3) Check the version of the scanner ROM version on the SLG board. (4) Replace the SYS board. (5) Replace the SLG board.
Code: F111
Description: Scanner response abnormality
Remedy: (1) Check if the harness connecting the SYS board and SLG board is disconnected or open circuited. (2) Check the version of the system ROM on the SYS board. (3) Check the version of the scanner ROM version on the SLG board. (4) Replace the SYS board. (5) Replace the SLG board.
Code: F130
Description: Invaid MAC addressData overwrite kit (GP-1050/1060) is taken off
Remedy: Compare the serial number of the equipment with a number displayed in 08-995. If they are different, enter the correct serial number at 08-995.
Code: F200
Description: Data overwrite kit (GP-1050/1060) is taken off
Remedy: Check the system ROM version (08-900) since the countermeasure to be taken varies. T377SY0*329 or later (* represents a letter of the alphabet corresponding to the destination.) Earlier than T377SY0*329 (* represents a letter of the alphabet corresponding to the destination.) Clear the service call “F200”. (Key in “0” at 08-633.) * When the Data overwrite kit (GP-1060) is removed from the equipment, the service call “F200” occurs.