- Code: U2 00
- Description: EEPROM read/write error (Serial communication error). EEPROM access process error
- Causes: EEPROM abnormality
- Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB.
- Code: U2 11
- Description: Counter check sum error (EEPROM). Check sum error of the counter area in the EEPROM
- Causes: EEPROM abnormality
- Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB.
- Code: U9 99
- Description: Panel language error. Improper language data
- Causes: A improper language data was downloaded.
- Remedy: Update LCD data.