  • Code: E1 84
  • Description: Network board communication interface error (Framing). A framing error occurs in communication between the MCU and the network board.
  • Causes: Improper connection of the network board cable Improper firmware Network board abnormality MCU abnormality
  • Remedy: Check connection of the network board cable. Update firmware. Replace the MCU and network board with new one.
  • Code: E7 01
  • Description: Image data error. 1) The memory capacity for the duplex model machine is improper. Insufficient memory capacity 2) Duplex setting for the single-surface model.
  • Causes: 1) The memory capacity on the MCU PWB is improper. 2) Wrong setting for the single-surface model.
  • Remedy: 1) Use SIM26-39 to check to confirm that the memory capacity is 64MB. If it is not 64MB, replace the MCU PWB. 2) If SIM26-04 is set to 1, set it to 0. If the setting is 0, replace the MCU PWB.
  • Code: E7 06
  • Description: Image data decode error. Image expansion error
  • Causes: MCU PWB error USB cable trouble
  • Remedy: Replace the MCU PWB. Replace the USB cable.
  • Code: E7 10
  • Description: Shading trouble (Black correction). The CCD black scan level is abnormal when the shading.
  • Causes: Improper connection of the CCD unit flat cable CCD unit abnormality MCU PWB abnormality
  • Remedy: Check connection of the CCD unit flat cable. Check the CCD unit.
  • Code: E7 11
  • Description: Shading trouble (White correction). The CCD white scan level is abnormal when the shading.
  • Causes: Improper connection of the CCD unit flat cable Dirt on the mirror, the lens, and the reference white plate Copy lamp lighting abnormality CCD unit abnormality MCU PWB abnormality (When occurred in the SPF/RSPF scan position.) Improper installation of the mirror unit
  • Remedy: Clean the mirror, lens, and the reference white plate. Check the light quantity and lighting status of the copy lamp (SIM 05-03). Check the MCU PWB.
  • Code: E7 16
  • Description: Abnormal laser output. When the laser output is stopped, HSYNC is detected.
  • Causes: Laser abnormality MCU PWB abnormality.
  • Remedy: Check the laser emitting diode operation. Replace the MCU PWB.
Error Code