PrintCopy.info service

Sharp ARC262M

Error Codes List page 20

  • Code: U7 00
  • Description: RIC communication trouble
  • Causes: RIC communication error, communication test error when turning on the power or after canceling the exclusive simulation.
  • Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness Check & Remedy Check the connector and the harness in the communication line. Turn OFF/ON the power to cancel the error. Case 2 Cause RIC control PWB trouble, control PWB (PCU) trouble, malfunction caused by noises Check & Remedy Turn OFF/ON the power to cancel the error.
  • Code: UC 02
  • Description: CPT-ASIC trouble (MFP PWB trouble)
  • Causes: Access abnormality to CPT-ASIC (ASIC does not operate normally.)
  • Remedy: Case 1 Cause CPT-ASIC abnormality MFP PWB abnormality Check & Remedy Turn OFF/ON repeatedly. If the trouble is not canceled, replace the MFP PWB.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us