PrintCopy.info service

Sharp AR651

Error Codes List page 29

  • Code: ECB
  • Description: Wrong size of inserter
  • Remedy: Is the paper size on the inserter tray consist with the size set at the copier control panel? Set the same paper size as that on the tray. Is the separation sensor working improperly? Replace the separation sensor. Perform the width adjustment of the inserter tray side guide.
  • Code: ECC
  • Description: Inserter feeding Jam
  • Remedy: Is the condition improved when the copier power switch is turned OFF/ON? 1. Replace the copier LGC board. 2. Replace the IPC board. 3. Replace the inserter control board.
  • Code: F07
  • Description: Communication error between SYS board and LGC board
  • Remedy: (1) Check if the connectors J114 and J105 on the SYS board are disconnected. (2) Check if the connector J4 on the SLG board is disconnected. (3) Check if the harness connecting the SYS and SLG boards is open-circuited and the connector pins are disconnected. (4) Check if the harness connecting the SYS board and LGC board is open-circuited and the connector pins are disconnected. (5) Check the version of the FROM on the SYS board. (6) Check the version of the MROM on the LGC board. (7) Check the version of the SROM on the SLG board. (8) Replace the SYS board. (9) Replace the SLG board. (10) Replace the LGC board.
  • Code: F10
  • Description: HDD formatting error
  • Remedy: (1) Initialize the HDD. (mode (08) - code "690"  2) (2) Check if the HDD is mounted. (3) Check if the specified HDD is mounted. (4) Check if the connector pins of the HDD are bent. (5) Check if the power supply connector is disconnected. (6) Check if the connector J107 on the SYS board is disconnected. (7) Replace the HDD. (8) Replace the SYS board. (9) Replace the harness.
  • Code: F11
  • Description: Communication error between SYS board and SLG board
  • Remedy: (1) Check if the connectors J114 and J105 on the SYS board are disconnected. (2) Check if the connector J4 on the SLG board is disconnected. (3) Check if the harness connecting the SYS and SLG boards is open-circuited and the connector pins are disconnected. (4) Check if the harness connecting the SYS board and LGC board is open-circuited and the connector pins are disconnected. (5) Check the version of the FROM on the SYS board. (6) Check the version of the MROM on the LGC board. (7) Check the version of the SROM on the SLG board. (8) Replace the SYS board. (9) Replace the SLG board. (10) Replace the LGC board.