  • Code: U2 12
  • Description: Adjustment value check sum error (EEPROM). Check sum error of the adjustment value area in the EEPROM
  • Causes: EEPROM abnormality
  • Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB.