PrintCopy.info service

Samsung SCX1000i

Error Codes List page 3

  • Code: 13
  • Display: Defective Motor Drive (LF : Line Feed)
  • Description: The motor drive of Line Feeder is not working.
  • Causes: 1. Check if the connector of LF (Line Feed) Motor is connected to the Main Board normally.
  • Remedy: 1. Try to replace the Main Board and the LF (Line Feed) Motor ASS’Y in sequence.
  • Code: 14
  • Display: Defective Motor Drive (CR : Carriage Return)
  • Description: The drive of CR (Carriage Return) Motor is not working.
  • Causes: 1. Check if the connector of CR (Carriage Return) Motor is connected to the Main Board normally.
  • Remedy: 1. Try to replace the Main Board, the CR (Carriage Return) Motor ASS’Y in sequence.
  • Code: 15
  • Display: Defective Motor Drive (SCAN)
  • Description: The TX Motor is not driven.)
  • Causes: 1. Check if the connector of Scan Motor is connected to the Main Board normally.
  • Remedy: 1. Try to replace the Main Board and the Scan Motor ASS’Y in sequence.
  • Code: 16
  • Display: Blank Page Print Out (When Copying)
  • Description: Blank page is printed out when copying.
  • Causes: 1. Check if the recording papers are inserted reversely. 2. Perform the CCD test in the service mode.
  • Remedy: 1. Insert the paper with the copy side. 2. In case the output waveform is abnormal in the CCD test, replace the CCD ASS’Y, while replace the Main Board in normal.
  • Code: 17
  • Display: Blank Page Print Out (When Receiving)
  • Description: Blank page is printed out when receiving.
  • Causes: 1. Check if the sender transmits the document properly. 2. Check if there remains some amount of ink. (Ex: COPY TEST/SELF TEST)
  • Remedy: 1. Replace the ink Cartridge. 2. If it is normal in the Copy Test and in the Self Test, try to replace the Main Board.
  • Code: 18
  • Display: Vertical Black Line (When Copying)
  • Description: Vertical black lines occur in the printing.
  • Causes: 1. Perform a CCD Test to check if the waveform is normal. 2. Clean the Cartridge nozzle.
  • Remedy: 1. If the CCD waveform is abnormal, replace the CCD ASS’Y. 2. Clean the nozzle and confirm again. 3. After confirming the CCD waveform and cleaning the nozzle, if the vertical black lines still occur, then try to replace the Main Board.