  • Code: U1-2112, U1-2120, U1-2132
  • Description: Fuser unit Failure: #Ul-2xxx. Tum off then on. Call for service if the problem perists
  • Causes: T11e temperature control of fuser unit is abnormal. (Open Heat EITor or Low Heat EITor or Over Heat EITor) I T11ennistor is defective. I Fuser unit connection is bad.
  • Remedy: 1) After checking the fuser installation, turn the machine off then on.
    2) Open the rear cover. Lift up the right side and release the rear cover.
    3) If there is no problem, remove 4 screws.
    4) Lift up the both levers. Then take off the fuser unit.
    5) Remove the Frame-cover-upper after removing 2 screws. And measure the thermostat continuity. Check if the thermostat is opened.
    6) Measure the LAMP-HALOGEN resistance value from the center and both sides. Check if it has the continuity.
    7) Check if the Draw-connector harness is correct. Check its color.
    8) Check if 2 thermistor connectors are connected properly.
    9) Measure the Thermistor resistance value from the center and both sides. Check if it has the continuity. (3 Red Circles)
    10)Check if the thermistor connector on the main board is connected properly.
    11) Check if the FDB connector is connected properly.
    12)Check if the voltage in user environment is in this range (80V ~ 140V, 160V ~ 260V).
    13)If there is no problems for above steps, update the firmware.
    14)Replace the FDB(JC44-00204A(220V)/JC44-00203A(110V)). If the problem persists, replace the SMPS(JC44-00092C(220V)/JC44-00091C(110V)) If the problem persists, replace the main board.
  • Code: U1-2115, U1-2116
  • Description: Fuser unit Failure: #U 1-2115. Turn off then on. Call for service if the problem persists
    Fuser unit Failure: #U 1-2116. Turn off then on. Call for service if the problem persists
  • Causes: The pressure control tmit(Cam tmit)ofthe fuser is abnonnal.
  • Remedy: 1) After checking the fuser installation, nun the machine off then on.
    2) Open the rear cover. Lift up the 1i ght side and release the rear cover.
    3) If there is no problem, remove 4 screws.
    4) Lift up the both levers. Then take off the fuser tmit.
    5) Remove the fuser side cover L/R. Check if the Actuator cam, Gear cam are assembled correctly.
    6) If there is no problem for above steps, assemble and reinstall fuser unit. Then turn the machine on.
    7) If the same error persists, perform a Memory Clear (backup data in SWS first); if that does not work try reinstalling the firmware.
    8) If the same error persists, replace the fuser unit(JC91–01177A (220V) / JC91–01176A (110V)) with new one.
    9) If the same error persists, replace the main board.
  • Code: U1-2117
  • Description: Fuser rnrit Failure: #Ul-2117. Tum off then on
  • Causes: The maclrine can't detect that the fuser turit is installed.
  • Remedy: 1) After checking the fuser installation, nun the maclrine off then on.
    2) Open the rear cover. Lift up the tight side and release the rear cover.
    3) If there is no problem, remove 4 screws.
    4) Lift up the both levers. Then take off the fuser turit.
    5) If there is no problem for above steps, assemble and reinstall fuser turit. Then nun the maclrine on.
    6) If the same error persists, execute the memory clear.
    7) If the same error persists, replace the fuser unit(JC91–01177A (220V) / JC91–01176A (110V)) with new one.
    8) If the same error persists, replace the main board.
  • Code: U1-2135, U1-23xx
  • Description: Fuser unit Failure: #Ul-2xxx. Tum off then on. Call for service if the problem perists
  • Causes: T11e temperature control of fuser unit is abnormal. (Open Heat EITor or Low Heat EITor or Over Heat EITor) I T11ennistor is defective. I Fuser unit connection is bad.
  • Remedy: 1) After checking the fuser installation, turn the machine off then on.
    2) Open the rear cover. Lift up the right side and release the rear cover.
    3) If there is no problem, remove 4 screws.
    4) Lift up the both levers. Then take off the fuser unit.
    5) Remove the Frame-cover-upper after removing 2 screws. And measure the thermostat continuity. Check if the thermostat is opened.
    6) Measure the LAMP-HALOGEN resistance value from the center and both sides. Check if it has the continuity.
    7) Check if the Draw-connector harness is correct. Check its color.
    8) Check if 2 thermistor connectors are connected properly.
    9) Measure the Thermistor resistance value from the center and both sides. Check if it has the continuity. (3 Red Circles)
    10)Check if the thermistor connector on the main board is connected properly.
    11) Check if the FDB connector is connected properly.
    12)Check if the voltage in user environment is in this range (80V ~ 140V, 160V ~ 260V).
    13)If there is no problems for above steps, update the firmware.
    14)Replace the FDB(JC44-00204A(220V)/JC44-00203A(110V)). If the problem persists, replace the SMPS(JC44-00092C(220V)/JC44-00091C(110V)) If the problem persists, replace the main board.
  • Code: U2-1111, U2-1112
  • Description: LSU Failure: #U2-1111. Please turn off then on.
    LSU Failure: #U2-1112. Please turn off then on.
  • Causes: LSU motor does not operate or it operates abnormally. / LSU Motor ready signal is abnormal.
  • Remedy: 1) Turn the machine off then on. Check for the LSU motor operation sound during warm-up.
    2) Print a demo page to check that the machine operates normally.
    3) If the problem persists, check the following : • If the LSU motor makes a sound, a) Enter SVC mode to check the LSU motor ready signal. b) Select “LSU Motor1 Run Ready”. c) Press ‘Start’ button. Check that the status has changed to ‘Executing -> Low -> High’. d) If the status has not changed, the motor ready signal is abnormal. Replace the LSU. • If the LSU motor does not makes a sound, a) Turn the machine off and open the side cover. Unplug and reconnect the LSU cable. Check that the LSU motor make a sound after turning the machine on. b) If the LSU cable is defective, replace it. Check that the LSU motor make a sound after turning the machine on. c) If the problem persists, replace the LSU(JC97-03877A).
  • Code: U2-1113, U2-1114
  • Description: LSU Failure: #U2-1113. Please turn off then on.
    LSU Failure: #U2-1114. Please turn off then on.
  • Causes: LSU motor does not operate or it operates abnormally. / LSU Motor ready signal is abnormal.
  • Remedy: 1) Turn the machine off then on. Check for the LSU motor operation sound during warm-up.
    2) Print a demo page to check that the machine operates normally.
    3) If the problem persists, check the following : • If the LSU motor makes a sound, a) Enter SVC mode to check the LSU motor ready signal. b) Select “LSU Motor1 Run Ready”. c) Press ‘Start’ button. Check that the status has changed to ‘Executing -> Low -> High’. d) If the status has not changed, the motor ready signal is abnormal. Replace the LSU. • If the LSU motor does not makes a sound, a) Turn the machine off and open the side cover. Unplug and reconnect the LSU cable. Check that the LSU motor make a sound after turning the machine on. b) If the LSU cable is defective, replace it. Check that the LSU motor make a sound after turning the machine on. c) If the problem persists, replace the LSU(JC97-03877A).