PrintCopy.info service

Samsung ProXpress M4080FX

Error Codes List page 2

  • Code: C2-1120, C2-1150
  • Description: Replace with new toner cartridge
    End of life, Replace with new toner cartridge
  • Causes: Toner cartridge is at the end of its life.
  • Remedy: 1) Open the front cover.
    2) Remove the toner cartridge.
    3) Install the new toner cartridge.
    4) Close the front cover.
  • Code: C2-1160, C2-1170
  • Description: Replace with new toner cartridge
    End of life, Replace with new toner cartridge
  • Causes: Toner cartridge is at the end of its life.
  • Remedy: 1) Open the front cover.
    2) Remove the toner cartridge.
    3) Install the new toner cartridge.
    4) Close the front cover.
  • Code: C2-1323, C2-1411
  • Description: Toner Failure: #C2-1323. Install toner cartridge again
    Toner cartridge is not installed. Install it
  • Causes: The toner cartridge is not installed properly.
  • Remedy: 1) Open the front cover.
    2) If the toner cartridge is not installed, install it. Try to test the machine again.
    3) If the toner cartridge is installed, remove it. Check if the contact terminal is contaminated or broken.
    4) Clean the contact terminal or replace the toner cartridge.
    5) Check if the CRUM harness is connected correctly. Reconnect it.
    6) If the harness is defective, replace it.
    7) Turn the machine off then on. Try to test the machine.
  • Code: C2-1512
  • Description: Toner cartridge is not compatible. Check users guide.
  • Causes: Toner cartridge is not compatible.
  • Remedy: 1) Open the front cover. Remove the toner cartridge.
    2) Check if the label information of the toner cartridge is same with the machine’s one. (ex. /SEE)
    3) If label information is different from the machine or the toner cartridge is not a samsung genuine, replace it with a new one.
  • Code: C2-1710, C2-1711, C2-1712
  • Description: Toner Cartridge Failure: #C2-1710. Call for service
    Toner Cartridge Failure: #C2-1711. Call for service
    Toner Cartridge Failure: #C2-1712. Call for service
  • Causes: The data of CRUM is not detected. / CRUM is defective.
  • Remedy: 1) Open the front cover. Check if the toner cartridge is installed.
    2) Remove and reinstall the toner cartridge.
    3) Check if the contact terminal is contaminated or broken. Clean the contact terminal.
    4) Check if the CRUM harness is connected correctly. Reconnect it.
    5) If the harness is defective, replace it.
    6) If the problem persists, replace the toner cartridge with new one.
  • Code: C6-1110
  • Description: Prepare new fuser unit
  • Causes: Fuser unit life will be expired soon.
  • Remedy: 1) Prepare new fuser unit.