  • Code: n06
  • Display: AIR PRESSURE TOO HIGH
  • Description: Operation was interrupted because the pressure of the compressed air was higher than permitted.
  • Remedy: This appears when the pressure of the compressed air is excessively high. First, readjust the air pressure to 0.5 to 0.65 MPa. When the display changes to ["ENTER" TO CONTINUE], press the [ENTER] key. The error is cleared and the operation resumes.
  • Code: n07
  • Display: OPERATING ERROR CAN'T RELEASE TOOL
  • Description: The tool cannot be released.
  • Remedy: This appears when the grasped tool could not be released for some reason. Switch off the power and make sure the air pressure is within the permitted range. Also make sure that no air hoses or cables have come loose. Switch on the power again. When [NOW CATCHING TOOL "ENTER" TO RELEASE] appears, press the [ENTER] key to try performing a forced release. (Be careful not to let the tool fall at this time.) If this operation fails to release the tool, then contact your Roland DG Corp. service center.