PrintCopy.info service

Roland AJ740i AdvancedJet

Error Codes List page 8

  • Code: 0203
  • Description: Head 4 is abnormally hot. Head 4 temperature has reached 58°C and above.
  • Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
  • Remedy: Check Flexible Cable connection around Head Head replacement
  • Code: 0204
  • Description: Head 5 is abnormally hot. Head 5 temperature has reached 58°C and above.
  • Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
  • Remedy: Check Flexible Cable connection around Head Head replacement
  • Code: 0205
  • Description: Head 6 is abnormally hot. Head 6 temperature has reached 58°C and above.
  • Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
  • Remedy: Check Flexible Cable connection around Head Head replacement