Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
Riso FR3950
Error Codes List page 4
|
|
- Code: T6
- Description: Pressure Detection Sensor Malfunction
- Causes: • In 8 seconds from turning ON of the main motor, the Pressure detection sensor is not turned ON/OFF.
- Remedy: Press <ALL RESET> key.
- Code: T68
- Description: SF3000 Power Supply Malfunction
- Causes: • When no power is supplied to the SF3000.
- Remedy: SF3000 OK signal H(SF3000 power-on)
- Code: T7
- Description: Communication error between FR and Digitizer
- Causes: • On occurrence of an error in communication between the System PCB and Digitizer III.
- Remedy: OFF -> ON
- Code: T78
- Description: Machine Model Selection Error
- Causes: • When there is no machine type which corresponds to the code having been set in System PCB.
- Remedy: Set the switch and turn OFF and ON the power
- Code: T79
- Description: Destination Spec. Code Error
- Causes: • When the code set (DIP switch) does not match the model set with the Hex. switch.
- Remedy: Set the switch and turn off and on the power
- Code: T8
- Description: Communication error between System PCB and Panel PCB
- Causes: • On occurrence of an error in communication between the System PCB and the Panel PCB.
- Remedy: OFF -> ON