  • Code: T15
  • Description: Flat Bed Read Pulse Motor Lock
  • Causes: • If the Image scanner home position sensor does not detect the Image scanner within 18898 pulses after the Flat bed read pulse motor is activated.
    • If the Image scanner ADF Shading sensor does not detect the Image scanner within 15748 pulses after the Flat bed read pulse motor is activated. • If the scanner home position sensor does not detect the Image scanner within 14,551 pulses(462 mm worth) after the Flat bed read pulse motor is activated during prescanning.
    • If the Image scanner is not release from the Image scanner home position sensor within 314 pulses after the Flat bed read pulse motor is activated.
    • If the Image scanner is not released from the Image scanner ADF Shading sensor within 314 pulses after the Flat bed read pulse motor is activated.
  • Remedy: Press <ALL RESET> key.
  • Code: T16
  • Description: Position C Sensor Malfunction
  • Causes: • If the Position C sensor status has not been changed from ON to OFF (or OFF to ON) within 8 seconds from the start of the Main Motor.
  • Remedy: Press <ALL RESET> key.
  • Code: T17
  • Description: Replace Battery
  • Causes: • When the battery voltage is less than 2.4 V at power-on, all reset, or end of operation.
  • Remedy: Power OFF -> ON
  • Code: T18
  • Description: Sorter Error
  • Causes: • If an error signal is received from the sorter.
  • Remedy: Power OFF -> ON
  • Code: T19
  • Description: Thermal Pressure Motor Lock
  • Causes: • If the TPH Pressure switch has not been depressed within 4 seconds after the TPH Pressure motor was activated to lower the TPH.
    • If the TPH Pressure switch has not been released within 4 seconds after the TPH Pressure motor was activated to raise the TPH.
  • Remedy: Press <ALL RESET> key.
  • Code: T2
  • Description: Elevator Motor Lock
  • Causes: • In 15 seconds from turning ON of the Elevator motor in upward direction, the Elevator upper limit sensor is not pushed.
    • In 15 seconds from turning ON of the Elevator motor in downward direction, the light path of the Elevator lower limit sensor is not blocked.
    • In 3 seconds from turning ON of the Elevator motor in upward direction, the Elevator lower sensor is held blocked.
    • In 3 seconds from turning ON of the Elevator motor in downward direction, the Elevator upper limit sensor is held pressed down.
  • Remedy: Press <ALL RESET> key.