PrintCopy.info service

Ricoh SP9100DN

Error Codes List page 1

  • Code: 300
  • Description: Charge corona output error
    The feedback voltage from the charge corona unit is detected too high 9 times.
  • Causes: • Charge corona power pack defective • Charge corona harness disconnected • Poor charge corona unit connection
  • Code: 303
  • Description: When the high voltage is output to the corona grid, feedback voltage exceeds the prescribed value 9 times.
  • Causes: • Charge corona power pack defective • Charge corona harness disconnected • Poor charge corona unit connection
  • Code: 304
  • Description: Charge grid circuit open
    When high voltage goes to the corona grid, feedback voltage is more than the set value 9 times. This feedback voltage is used to update PWM for output control.
  • Causes: • Charge corona unit defective or disconnected • Charge corona harness defective • Charge corona power pack is defective.
  • Code: 305
  • Description: Charge corona wire cleaner error 1
    The charge cleaner pad does not arrive at the home position: Motor locked within 4 s after switching on, or does not lock within 30 s. Motor locked within 10 s after reversing, or does not lock within 30 s.
  • Causes: • Charge corona wire cleaner motor defective • Motor driver defective
  • Code: 306
  • Description: Charge corona wire cleaner error 2
    Charge coronal motor is disconnected. (The current at the charge corona motor is detected less than 83 mA.)
  • Causes: • Charge corona wire cleaner motor connector is defective, connected
  • Code: 310
  • Description: Potential sensor calibration error 1
    During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (–100V, –800V) are applied to the drum
  • Causes: • IOB defective • OPC connector defective • Development power pack defective