  • Code: 547
  • Description: Zero cross signal malfunction
    Zero cross signals are not detected within 5 seconds after the main power switch is turned on, or are not detected within 1 second after operation begins.
  • Causes: • Power supply board defective
    • BICU defective
  • Code: 559
  • Description: Jam error detected 3 times in succession
    • The exit sensor and the duplex sensor detect a paper jam 3 times in succession
    • This condition can occur when SP 1159 1 is set to ‘on’. The default is ‘off’.
  • Causes: Paper jams can occur for the following reasons.
    • Dampness
    • Paper curl
    • Incorrect paper setting in the paper tray
    • Stripper pawls coming apart
  • Code: 590
  • Description: Left exhaust fan motor error
    The CPU detects an exhaust fan lock signal for more than 5 seconds.
  • Causes: • Loose connection of the exhaust fan motor
    • Too much load on the motor drive
  • Code: 928
  • Description: Memory error
    The machine detects a discrepancy in the write/read data during its write/read test (done at power off/on and at recovery from low power or night/off mode).
  • Causes: • Memory defective
    • BICU defective
    • Poor connection between BICU and memory
  • Code: 981
  • Description: NVRAM error
    The machine detects a discrepancy in the NVRAM write/read data when attempting to save actual data to the NVRAM (i.e. during actual use).
  • Causes: • NVRAM defective
    • Poor connection between BICU and NVRAM
    • NVRAM is not connected
    • BICU defective
  • Code: 982
  • Description: Localization error
    The localization settings in the nonvolatile ROM and RAM are different (SP5807).
  • Causes: • First machine start after the NVRAM is replaced
    • Incorrect localization setting
    • NVRAM defective