Description: Software Error
The software performs an unexpected function and the program cannot continue. Recovery processing allows the program to continue.
Causes: • Software defective, re-boot
Code: SC994
Description: Operation Panel Management Records Exceeded
An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. This can occur if there if there are too many application screens open on the operation panel.
Causes: • No action required because this SC does not interfere with operation of the machine.
Code: SC997
Description: Application Selection Error
An application did not start after pressing the appropriate key on the operation panel.
Causes: • Software bug; change the firmware for the application that failed • A RAM or DIMM option required by the application is not installed or not installed correctly.
Code: SC998
Description: Application Start Error
Register processing does not execute for any application within 60 s after the machine is powered on. No application starts correctly, and all end abnormally.
Causes: • Software defective; change the firmware for the application that failed
• A RAM or DIMM option required by the application is not installed or not installed correctly.
Code: SC999
Description: Program Download Error
The program download from the SD card does not execute normally. This SC is not logged.
Causes: • Card installed incorrectly
• BCU defective
• SD card defective
• Controller board defective
• Power down during program downloading
• Wrong type of card inserted (see Section 5 “Service Tables” for downloading procedures)