PrintCopy.info service

Ricoh G179 SP8200DN AL-P1

Error Codes List page 1

  • Code: 202
  • Description: Polygon motor error 1: ON timeout
    The polygon mirror motor does not reach the targeted operating speed within 10 sec. after turning on or changing speed
  • Causes: • Polygon motor/driver board harness loose or broken • Polygon motor/driver board defective • Laser optics unit defective • IPU defective
  • Code: 203
  • Description: Polygon motor error 2: OFF timeout
    The polygon mirror motor does not leave the READY status within 3 sec. after the polygon motor switched off.
  • Causes: • Polygon motor/driver board harness loose or broken • Polygon motor/driver board defective • Laser optics unit defective • IPU defective
  • Code: 204
  • Description: Polygon motor error 3: XSCRDY signal error
    The SCRDY_N signal remains HIGH for 200 ms while the LD unit is firing.
  • Causes: • Polygon motor/driver board harness loose or broken • Polygon motor/driver board defective • Laser optics unit defective • IPU defective
  • Code: 220
  • Description: Laser synchronizing detection error: start position LD0
    The laser synchronizing detection signal for the start position of the LDB is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally
  • Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LD board • Defective BCU
  • Code: 221
  • Description: Laser synchronizing detection error: start position LD1
    The laser synchronizing detection signal for the start position of the LDB is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
  • Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LD board • Defective BCUa
  • Code: 230
  • Description: FGATE ON error
    The FGATE signal does not assert within the prescribed time. (The BCU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
  • Causes: • BCU defective • BCU, Controller board harness loose or broken • Controller board defective.