Causes: When registering the form, it is not available to register due to the limitation of the number of registration. With referring the handling manual, delete unnecessary ones after checking the registered form. Or delete the unnecessary forms by the print command.
Code: 116-742
Description: Logo registration error
Causes: When registering the logo data, it is not available to register due to the limitation of the number of registration. With referring the handling manual, delete unnecessary ones after checking the registered logo. Or delete the unnecessary logos by the print command.
Code: 116-743
Description: Form/Logo size over flow
Causes: The received data (form /logo) is over te registered buffer size. With referring the handling manual, add the memory size of form registration area in the memory setting. Or install HDD.
Code: 116-745
Description: ART Command Error
Causes: An error is caused to ART command. Check the print data, delete the command to cause the error, and execute printing again.
Code: 116-746
Description: Form composition error
Causes: The specified form is not registered. Use the registered form, or register the required form.