Description: Scope-FD send error detected by Controller(Framing error)
Causes: Framing error is caused because ACK is not received by resend in twice. If the trouble is not recovered by powering OFF and ON, execute the following. - Check the connection of HVPS/MCU connect harness. - If the trouble is still caused, replace HVPS/MCU PWB.
Code: 003-348
Description: Send error detected by Controller Detect incorrect command in sending ENOSTR
Causes: Power OFF and ON
Code: 003-349
Description: Send error detected by Controller Sending under runESPIPE
Causes: Power OFF and ON
Code: 003-350
Description: Varieties of errors detected by Controller EIO
Causes: Power OFF and ON
Code: 003-354
Description: Parity error is caused in receiving a status from IOT
Causes: It is caused when receiving NAK which reporting the communication fail. Check the connection of HVPS/MCU connect harness. If the trouble is still caused, replace HVPS/MCU PWB.
Code: 003-356
Description: Overrun is caused in receiving a status from IOT
Causes: It is caused when receiving NAK which reporting the communication fail.Check the connection of HVPS/MCU connect harness. If the trouble is still caused, replace HVPS/MCU PWB.