Description: Ozone Ventilation Fan Motor’s failure to turn
An Ozone Fan Lock signal is detected for a continuous 3-sec. period while the Ozone Ventilation Fan Motor is turning.
Remedy: 1 Ozone Ventilation Fan Motor turns when the Start key is pressed. NO: Check connector for connection. Check fan for overload. 2 Ozone Ventilation Fan Motor rotation when the Start key is pressed: the voltage across PJ10I-15 on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. NO: Change Master Board. 3 Ozone Ventilation Fan Motor rotation when the Start key is pressed: the voltage across CN2HV3-3 on High Voltage Unit 3 and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change High Voltage Unit 3.
Code: C004E
Description: Power Supply Cooling Fan Motor’s failure to turn
A Power Supply Cooling Fan Lock signal is detected for a continuous 3-sec. period while the Power Supply Cooling Fan Motor is turning.
Remedy: 1 Power Supply Cooling Fan Motor turns when the Start key is pressed. NO: Check connector for connection. Check fan for overload. 2 Power Supply Cooling Fan Motor rotation when the Start key is pressed: the voltage across PJ13PU1-3 on DC Power Supply 1 and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change DC Power Supply 1.
Code: C0060
Description: Fusing Drive Motor’s failure to turn
A Fusing Drive Motor Lock signal remains faulty for a predetermined continuous period of time while the Fusing Drive Motor is turning.
Remedy: 1 Fusing Drive Motor turns when the Start key is pressed. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). 2 Fusing Drive Motor rotation when the Start key is pressed: the voltage across PJ13I-1A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board. 3 Fusing Drive Motor rotation when the Start key is pressed: the voltage across PJ7PU1- 4 on DC Power Supply 1 and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO Change DC Power Supply 1.
Code: C0061
Description: Fusing Drive Motor turning at abnormal timing
The Fusing Drive Motor Lock signal remains faulty for a predetermined continuous period of time while the Fusing Drive Motor remains stationary.
Remedy: 1 Fusing Drive Motor rotation while it is being energized: the voltage across PJ13I-1A on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
Code: C0094
Description: 2nd Image Transfer Roller pressure/retraction failure
• The 2nd Image Transfer Pressure Position Sensor is not activated (retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its retracting motion. • The 2nd Image Transfer Pressure Position Sensor is not deactivated (not the retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its pressing motion.
Remedy: 1 While the 2nd Image Transfer Pressure/ Retraction Clutch is supposed to be deenergized during timing of pressure/retraction operation: the voltage across PJ14I-9A on Master Board and GND is DC 24 V when the clutch is deenergized and DC 0 V when the clutch is energized. YES: Check connector for connection. Check for overload. Change clutch. NO: Change Master Board. 2 I/O check for 2nd Image Transfer Pressure Position Sensor operation during pressure/ retraction operation: the voltage across PJ14I-6B on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (pressed position). YES: Change Master Board. NO: Correct actuator. Check sensor connector for connection. Change sensor.
Code: C0096
Description: 1st Image Transfer Roller pressure/retraction failure
• The 1st Image Transfer Retraction Position Sensor is not activated (retracted position) within 3 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning. • The 1st Image Transfer Retraction Position Sensor is not deactivated (pressed position) within 1.5 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning.
Remedy: 1 1st Image Transfer Pressure/Retraction Motor turns during pressure/retraction operation. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). Change motor. Change Master Board. 2 I/O check for 1st Image Transfer Retraction Position Sensor operation during pressure/ retraction operation: the voltage across PJ17I-1A on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (retracted position). YES: Change Master Board. NO: Correct actuator. Check sensor connector for connection. Change sensor.