Description: PIC communication error
• A sampling lock is not received after the lapse of a predetermined period of time after IREQ has been received during AIDC sampling of image stabilization sequence or registration adjustment. • There is an open-circuit in the communication harness between the PIC Board and Master Board. • Either the PIC Board or Master Board is faulty.
Remedy: 1 Harnesses and connectors connecting PIC Board to Master Board are in good condition. NO: Change harnesses. Reconnect connectors. 2 The problem has been eliminated through the check of step 1. NO: Change PIC Board. 3 The problem is eliminated after the PIC Board has been replaced. NO: Change Master Board.oard.
Code: C3A01
Description: PIC Board malfunction
The PIC Board is faulty.
Remedy: 1 The same malfunction recurs even after the malfunction has been reset, Power Switch turned OFF and ON, and the power cord plugged out and back in. YES: Change PIC Board.
Code: C3FFF
Description: ROM contents fault detected upon start
The system fails to rewrite flash memory during updating.
Remedy: 1 This malfunction occurs when an attempt is made to update firmware (rewriting of flash ROM). YES: Try downloading again. 2 The problem has been eliminated through the check of step 1. NO: Change Master Board.