  • Code: C730
  • Description: Broken external temperature thermistor wire
    • The input voltage is above 4.5 V.
  • Causes: Poor contact of the humidity sensor PCB connector terminals.Defective external temperature thermistor.
  • Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable. Replace the humidity sensor PCB.
  • Code: C731
  • Description: Short-circuited external temperature thermistor
    • The input voltage is below 0.5 V.
  • Causes: Poor contact of the humidity sensor PCB connector terminals. Defective external temperature thermistor.
  • Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable. Replace the humidity sensor PCB.