Error Codes List page 1

  • Code: C0060
  • Description: Type mismatch error Install the SSD for different model. Or, it is not possible to communicate with some units.
  • Remedy: 1 Checking the SSD Installed SSD containing firmware which is not for the applicable model. Install SSD containing firmware which is for the applicable model. Detaching and reattaching the SSD 2 Checking the connection The connector is not connected properly, or the wire is faulty. Reconnect the connector which connect to the below unit. If there is no continuity, replace the wire. - Drum unit - Developer unit - Primary transfer unit - Fuser unit Maintenanc e parts replacemen t procedures
  • Code: C0100
  • Description: Backup memory device error An abnormal status is output from the flash memory.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on. 2 Checking the main PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB. Section 8 "PWBs" Detaching and reattaching the Main PWB
  • Code: C0120
  • Description: MAC address data error The MAC address data is incorrect.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on. 2 Checking the MAC address The MAC address is incorrect. Replace the main PWB when the MAC address is not indicated on the network status page. Detaching and reattaching the Main PWB
  • Code: C0130
  • Description: Backup memory reading/writing error The reading or writing into the flash memory is unavailable
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on. 2 Checking the main PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB. Section 8 "PWBs" Detaching and reattaching the Main PWB
  • Code: C0150
  • Description: Engine EEPROM reading / writing error 1. Five times consecutive detection of no response from the device for more than 5ms on reading / writing. 2. Data read in 2 places does not match 8 consecutive times. 3. Writing data and reading data does not match 8 consecutive times.
  • Remedy: 1 Resetting the main power The EEPROM on the engine PWB does not operate properly. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on. 2 Checking the EEPROM on the engine PWB The EEPROM is not properly attached. Reattach the EEPROM on the engine PWB. Detaching and reattaching the EEPROM (Section 4 "Notes when replacing the engine PWB") 3 Checking the EEPROM on the engine PWB The EEPROM is faulty. Replace the EEPROM on the engine PWB and execute U169. Then, compare to previously output U000 maintenance report, re-enter the setting value for U053, U100, U101, U106, U140, U161, U464, U252, U034, and execute the maintenance mode in following order. U119 > U469[Manual] > U140[AC Calib] > U464[Calib] > U155[Calibration] (prepare the empty waste toner box) Detaching and reattaching the EEPROM (Section 4 "Notes when replacing the engine PWB") Maintenanc e Mode List 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB
  • Code: C0160
  • Description: EEPROM data error The data read from the EEPROM is judged as abnormal.
  • Remedy: 1 Resetting the main power The EEPROM on the engine PWB does not operate properly. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on. 2 Executing U021 The storage data in the EEPROM on the engine PWB is faulty. Execute U021. Maintenanc e Mode List 3 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the engine PWB and execute U169. Then, compare to previously output U000 maintenance report, re-enter the setting value for U053, U100, U101, U106, U140, U161, U464, U252, U034, and execute the maintenance mode in following order. U119 > U469[Manual] > U140[AC Calib] > U464[Calib] > U155[Calibration] (prepare the empty waste toner box) Detaching and reattaching the EEPROM (Section 4 "Notes when replacing the engine PWB") Maintenanc e Mode List