Error Codes List page 1

  • Code: C0100
  • Description: Backup memory device error
  • Causes: The abnormal status is output from the flash memory.
  • Remedy: 1 Resetting the main power The EEPROM does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Reinstalling the EEPROM The EEPROM is not properly attached. Reattach the EEPROM on the main/engine PWB.
    3 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the main/engine PWB and execute U004 when C0180 appears
    4 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0120
  • Description: MAC address data error
  • Causes: MAC address data was incorrect data.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Main/engine PWB replacement The MAC address is incorrect. Replace the main/engine PWB when the MAC address is not indicated on the network status page.
  • Code: C0130
  • Description: Backup memory reading/writing error
  • Causes: The reading or writing into the flash memory is unavailable.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0140
  • Description: Backup memory data error
  • Causes: The data read from the flash memory is judged as abnormal at the startup.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0150
  • Description: EEPROM writing / reading error
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Reinstalling the EEPROM The EEPROM is not properly attached. Reattach the EEPROM on the main/engine PWB.
    3 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the main/engine PWB.
    4 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0160
  • Description: EEPROM data error
  • Causes: The data read from the EEPROM is judged as abnormal.
  • Remedy: 1 Resetting the main power The EEPROM does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the main/engine PWB and execute U004.