PrintCopy.info service

Konica-Minolta bizhub Pro 1050e

Error Codes List page 55

  • Code: SC77-49
  • Description: When non-volatile memory is being accessed, no response is obtained for a specified period of time.
  • Causes: FD control board (FDCB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC77-58
  • Description: When the FD is unready, a signal to start operations is received from the main body.
  • Causes: Irregular operations. Recovery by turning the power ON and OFF.
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC77-59
  • Description: The communication message queue between the tasks in the FD is full.
  • Causes: Irregular operations. Recovery by turning the power ON and OFF.
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC80-40
  • Description: The ISW information is not written. Or, the ROM check of the FD results in an error.
  • Causes: FD control board (FDCB) Wiring harness between the FDCB and the main bo
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC80-42
  • Description: The ISW information is not written. Or, the ROM check of the FNS results in an error.
  • Causes: FNS control board (FNSCB) Wiring harness between the FNSCB and the main body
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).