Remedy: 1 Power switch Turn OFF and ON the power switch, and check if the Abort code appears again. NO When not reappearing, continuous use is carried out, and it is checked whether an abort code occurs. 2 Connector connection Check the connector for proper connection on MFPB and correct as necessary. NO It will correct, if connector connection has abnormalities. 3 Firmware Update the firmware to the latest version, and check if the Abort code appears again. NO After conducting firmware updating, check the firmware version No. and confirm that the firmware has been normally updated. 4 MFP board Replace MFPB