Catalog
Sign In
Contacts
Forum
Eng
Konica-Minolta Di551
Error Codes List page 4
Error Code:
All codes
E22-03
E23-04
E46-01
E46-02
E46-03
E46-05
E46-06
E46-08
E46-12
E46-13
E46-14
E46-15
E46-16
E46-17
E46-19
E46-21
E46-23
E46-24
E46-25
E46-26
E46-27
E46-29
E46-30
E46-31
E46-32
E46-33
E46-34
E46-35
E46-80
E46-81
E46-82
E46-83
E46-90
E46-91
E46-99
E50-01
E50-02
E50-03
E50-04
E50-05
E50-10
E50-11
E56-02
E70-1
E70-2
E80-01
E80-02
E80-03
E90-01
E90-02
F-77-15
F13-01
F13-02
F18-10
F18-11
F18-20
F18-21
F18-30
F18-31
F18-40
F18-41
F18-50
F18-51
F18-60
F21-01
F21-02
F21-03
F21-05
F21-06
F21-07
F22-01
F22-02
F23-01
F23-02
F23-03
F28-01
F28-02
F28-03
F29-01
F29-03
F29-04
F29-05
F29-06
F29-07
F29-08
F32-01
F32-02
F32-03
F32-04
F33-01
F34-01
F34-02
F35-01
F35-02
F35-03
F36-01
F36-02
F41-01
F41-02
F42-01
F42-02
F46-40
F46-41
F46-42
F46-43
F46-50
F46-51
F46-60
F46-61
F46-62
F46-63
F46-64
F52-01
F52-02
F53-01
F62-01
F77-1
F77-11
F77-12
F77-13
F77-14
F77-2
F77-21
F77-22
F77-25
F77-26
F77-3
F77-4
F77-41
F77-42
F77-43
F77-44
F77-46
F77-47
F77-5
F77-52
F77-53
F77-54
F77-55
F77-56
F77-57
F77-58
F77-6
F77-7
F77-8
F77-81
F77-91
F77-92
F80-11
F80-30
F80-31
F80-32
F80-40
F80-41
F92-01
SC77-01
SC77-02
SC77-03
SC77-04
SC77-05
SC77-06
SC77-11
SC77-12
SC77-54
SC77-55
SC77-81
page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
Code: E46-25
Description: Image control abnormality
AOC/AGC error • The light blocking cover and lens cover are removed from the scanner section. • The A/D converter board connector is disconnected. • The power cable of A/D converter board is disconnected. • The IC protector on the A/D converter board is blown out. • The exposure lamp intensity is excessive. • The exposure lamp does not light.
Causes: ADB (A/D conversion board) L1 (exposure lamp)
Code: E46-26
Description: Image control abnormality
Correction data saved on a resolution basis is not found.
Causes: ICB (image control board)
Code: E46-27
Description: Image control abnormality
The density correction γ curve cannot be generated properly.
Causes: ICB (image control board)
Code: E46-29
Description: Image control abnormality
Calibration start error.
Causes: ICB (image control board) ICB program
Code: E46-30
Description: Image control abnormality
Calibration end error
Causes: ICB (image control board) ICB program
Code: E46-31
Description: Image control abnormality
An attempt was made to perform APC initial sampling before completion of MPC.
Causes: ICB (image control board) ICB program