PrintCopy.info service

Konica-Minolta Di551

Error Codes List page 29

  • Code: SC77-12
  • Description: FN-113/122 abnormality
    Stapling Motor 1 is not deenergized even after the lapse of a given period of time after it has been energized (to start a stapling sequence).
  • Causes: PWB-A (Control Board) Stapling Unit 1
  • Code: SC77-54
  • Description: FN-113/122 abnormality
    The Punch Motor Pulse Sensor (PC15) does not go from LOW to HIGH, or vice versa, even after the lapse of a given period of time after M11 has been energized.
  • Causes: PC15 (Punch Motor Pulse Sensor) M11 (Punch Motor) PWB-A (Control Board)
  • Code: SC77-55
  • Description: FN-113/122 abnormality
    The Hole Punch Position Switch (S4) is not actuated or deactuated even after the lapse of a given period of time after M14 has been energized. *1 : U.S.A. and Canada only
  • Causes: Punch Unit M14 (Hole Position Selector Motor) PWB-A (Control Board)
  • Code: SC77-81
  • Description: FN-113/122 abnormality
    The Transport Unit Entrance Switching Sensor (PC23) does not go from LOW to HIGH even after the lapse of a given period of time after M17 has been energized to select the U path. The Transport Unit Entrance Switching Sensor (PC23) does not go from HIGH to LOW even after the lapse of a given period of time after M17 has been energized to select the straight path.
  • Causes: PC23 (Transport Unit Entrance Switching Sensor) M17 (Transport Unit Entrance Switching Motor) PWB-A (Control Board)