Description: Image control abnormality
Decompression error of image data.
Causes: ICB (image control board) Expansion memory
Code: E46-08
Description: Image control abnormality
When APC is performed, the index sensor output does not change.
Causes: Write section ICB (image control board) power connector
Code: E46-12
Description: Image control abnormality
Compression of the read image and decompression in the page memory are not completed within the specified time after negation of SVV.
Causes: ICB (image control board)
Code: E46-13
Description: Image control abnormality
During image read, image data compression from the scanner to the memory is not completed within the specified time. Image data decompression from the scanner to the page memory is not completed within the specified time. SVV is not detected within the specified time.
Causes: PRCB (printer control board) ICB (image control board)
Code: E46-14
Description: Image control abnormality
During image read, image data decompression from the memory to the printer is not completed within the specified time. Image data output from the page memory to the printer is not completed within the specified time. PVV is not detected within the specified time.
Causes: PRCB (printer control board) ICB (image control board)
Code: E46-15
Description: Image control abnormality
During image write, improper processing was performed. For example, the decompression device was accessed although there was no resource.