  • Code: E001-0001-05
  • Description: Fixing Thermistor high temperature detection error.
    The Fixing Main Thermistor detected a high temperature error.
  • Causes: - Harness connecting the DC Controller PCB (J122), Drawer Unit (J5012)
    - Power Supply Unit
    - DC Controller PCB
    - Feed/Drum Driver PCB
    - Relay PCB
    - Fixing Motor (M21)
    - Fixing Film Unit
    - Pressure Roller Unit
    - Shutter Unit
    - Fixing Drive Unit
    - 27T Gear
    - Fixing Unit
  • Remedy: - Check COPIER> DISPLAY> ANALOG> FIX-E.
    a. In the case of below 283 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power.
    b. In the case of 283 deg C or higher, check/replace the related harness/cable, connector and parts.
    [Caution] When replacing the Fixing Film Unit, turn the power ON after replacement. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.
  • Code: E001-0002-05
  • Description: Fixing Thermistor high temperature detection error.
    The Fixing Thermistor (Front) detected a high temperature error.
  • Causes: - Harness connecting the DC Controller PCB (J122), Drawer Unit (J5012)
    - Power Supply Unit
    - DC Controller PCB
    - Feed/Drum Driver PCB
    - Relay PCB
    - Fixing Motor (M21)
    - Fixing Film Unit
    - Pressure Roller Unit
    - Shutter Unit
    - Fixing Drive Unit
    - 27T Gear
    - Fixing Unit
  • Remedy: - Check COPIER> DISPLAY> ANALOG> FIX-E2.
    a. In the case of below 295 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power.
    b. In the case of 295 deg C or higher, check/replace the related harness/cable, connector and parts.
    [Caution] When replacing the Fixing Film Unit, turn the power ON after replacement. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.
  • Code: E001-0003-05
  • Description: Fixing Thermistor high temperature detection error.
    The Fixing Thermistor (Rear) detected a high temperature error.
  • Causes: - Harness connecting the DC Controller PCB (J122), Drawer Unit (J5012)
    - Power Supply Unit
    - DC Controller PCB
    - Feed/Drum Driver PCB
    - Relay PCB
    - Fixing Motor (M21)
    - Fixing Film Unit
    - Pressure Roller Unit
    - Shutter Unit
    - Fixing Drive Unit
    - 27T Gear
    - Fixing Unit
  • Remedy: - Check COPIER> DISPLAY> ANALOG> FIX-E3.
    a. In the case of below 295 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power.
    b. In the case of 295 deg C or higher, check/replace the related harness/cable, connector and parts.
    [Caution] When replacing the Fixing Film Unit, turn the power ON after replacement. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR
  • Code: E001-0011-05
  • Description: Fixing Thermistor high temperature detection error.
    The Fixing Film Unit Main Thermistor detected an abnormally high temperature.
  • Causes: - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404)
    - Fixing Film Unit
    - Pickup Driver PCB (UN4)
  • Remedy: Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.
    1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Main Thermistor.
    2. Pull out the Fixing Feed Unit and check "FIX-UC".
    a. In the case of below 240 deg C, replace the Fixing Film Unit.
    b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again.
    b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit.
    b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
  • Code: E001-0012-05
  • Description: Fixing Thermistor high temperature detection error.
    The Fixing Film Unit Sub Thermistor 1 detected an abnormally high temperature.
  • Causes: - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003)
    - Fixing Film Unit
    - Pickup Driver PCB (UN4)
  • Remedy: Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.
    1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Sub Thermistor 1.
    2. Pull out the Fixing Feed Unit and check "FIX-UC2".
    a. In the case of below 240 deg C, replace the Fixing Film Unit.
    b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC2" again.
    b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit.
    b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
  • Code: E001-0013-05
  • Description: Fixing Thermistor high temperature detection error.
    The Fixing Film Unit Sub Thermistor 2 detected an abnormally high temperature.
  • Causes: - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003)
    - Fixing Film Unit
    - Pickup Driver PCB (UN4)
  • Remedy: Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.
    1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Sub Thermistor 2. 2. Pull out the Fixing Feed Unit and check "FIX-UC3".
    a. In the case of below 240 deg C, replace the Fixing Film Unit.
    b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC3" again.
    b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit.
    b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.