Description: There is a fault in IPC initialization.
At time of power-on, the communications IC on the main controller PCB does not become ready within 3 sec after start-up.
Remedy: - Check the connection of the cable.
Code: E710-0002
Description: There is a fault in IPC initialization.
At power-on, the machine communication IC has detected an error.
Remedy: - Check the connection of the cable.
Code: E711-0001
Description: There is a fault in the IPC communication.
After power-on, the occurrence of an error has been written 4 times in 1.5 sec to the error register of the communications IC on the main controller PCB.
Remedy: - Check the connection of the cable.
Code: E711-0002
Description: There is a fault in the IPC communication.
After power-on, the machine communication IC has detected an error.
Remedy: - Check the connection of the cable.
Code: E713-0000
Description: There is a sorter IPC error.
An error has been detected in the sorter communication IC.
Remedy: - Check the connection of the cable. - Replace the finisher controller PCB. - Replace the DC controller PCB.
Code: E717-0001
Description: There is a fault in the communication with the NE controller. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
An error has occurred at time of NE controller start-up. The NE controller that was connected before power-off is not connected at power-on.