Description: The hard disk is faulty.
At time of start-up, the HDD fails to reach a specific temperature within a specific period of time.
Remedy: - Replace the hard disk. - Replace the DC controller PCB.
Code: E609-0009
Description: The hard disk is faulty.
At time of a sleep shift, the temperature is below a specific level.
Remedy: - Replace the hard disk. - Replace the DC controller PCB.
Code: E610
Description: The HDD encryption key is faulty. (hardware composition error, initialization error, ID key error, ID processing error)
Remedy: - Check the hardware composition. - Turn off and then on the main power.
Code: E611-0000
Description: retried reboot due to SRAM crash and the like during the shutdown recovery job execution
SRAM data were broken and the stored job information cannot be read; this causes the repeated reboot trials to recover the power shutdown, and thus the redundant job transmission. This phenomenon triggers E code.
Remedy: Clear SRAM to cancel the shutdown recovery job.
Code: E612
Description: error in postponement Timing: when starting the host machine
Remedy: Write the correct license and new serial numbers and turn off/on the power switch. - Turn off and then on the main power.
Code: E674-0001
Description: There is a fault in the communication between the fax controller PCB (2-line) and the main controller PCB.
An attempt to set fax device mode has failed.
Remedy: - Check the connection of the cable between the fax controller PCB (2-line) and the main controller PCB. - Replace the ROM DIMM of the fax controller PCB (2-line). - Replace the fax controller PCB (2-line). - Replace the main controller PCB.