PrintCopy.info service

Canon iR1730

Error Codes List page 2

  • Code: E004-0000
  • Description: Thermistor disconnection detection error
    Connector disconnection was detected for 30 msec on end.
  • Remedy: 1. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB) 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB (PCB1).
  • Code: E010-0001
  • Description: Main Motor (M2) rotation error
    Detection was performed every 100 msec since the start of drive and there had been no lock detection signal in 2 seconds.
  • Remedy: 1. Check the connector between the Main Motor and the DC Controller PCB (J203). 2. Replace the Main Motor (M2). 3. Replace the DC Controller PCB (PCB1).
  • Code: E010-0002
  • Description: Main Motor (M2) rotation error
    Detection was performed every 100msec during the drive (after the lock detection) and the lock signal was not detected 5 times in a row (in 500 msec).
  • Remedy: 1. Check the connector between the Main Motor and the DC Controller PCB (J203). 2. Replace the Main Motor (M2). 3. Replace the DC Controller PCB (PCB1).
  • Code: E013-0001
  • Description: Error in rotation of Waste Toner Motor (M3)
    Lock detection flag was monitored every 2msec, and the same level was detected 600 times in a row.
  • Remedy: 1. Check the connector connection between the Waste Toner Motor and the DC Controller PCB (J209). 2. Replace the Waste Toner Motor (M3). 3. Replace the DC Controller PCB (PCB1).
  • Code: E014-0001
  • Description: Fixing Motor (M1) rotation error
    Detection was performed every 100 msec since the start of drive and there had been no lock detection signal in 2 seconds.
  • Remedy: 1. Check the connector connection between the Fixing Motor and the DC Controller PCB (J203). 2. Replace the Fixing Motor (M1). 3. Replace the DC Controller PCB (PCB1)
  • Code: E014-0002
  • Description: Fixing Motor (M1) rotation error
    Detection was performed every 100 msec during the drive (after the lock detection) and the lock signal was not detected 5 times in a row (in 500 msec).
  • Remedy: 1. Check the connector connection between the Fixing Motor and the DC Controller PCB (J203). 2. Replace the Fixing Motor (M1). 3. Replace the DC Controller PCB (PCB1).
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us