Causes: Since the startup of the Controller Fan, the Fan was locked for a specified consecutive period of time.
Remedy: 1. Check power supply to the Controller Fan. 2. Replace the Controller Fan.
Code: E805 0000
Description: Delivery cooling fan (FM1) error
Causes: • FAN driving: When "Lock signal = High" is detected more than 5 sec or more continuously. • FAN suspended: When "Lock signal = Low" is detected more than 10 sec or more continuously
Remedy: 1. Check connection to the delivery cooling fan (FM1). 2. Replace the delivery cooling fan (FM1).
Code: E805 0001
Description: Image formation part cooling fan (FM3) error
Causes: • FAN driving: When "Lock signal = High" is detected more than 5 sec or more continuously. • FAN suspended: When "Lock signal = Low" is detected more than 10 sec or more continuously.
Remedy: 1. Check connection to the Image formation part cooling fan (FM3). 2. Replace the Image formation part cooling fan (FM3).
Code: E805 0002
Description: Power supply cooling fan (FM2) error
Causes: • FAN driving: When "Lock signal = High" is detected more than 5 sec or more continuously. • FAN suspended: When "Lock signal = Low" is detected more than 10 sec or more continuously.
Remedy: 1. Check connection to the power supply cooling fan (FM2). 2. Replace the power supply cooling fan (FM2).
Code: E996 0071
Description: Sequence jam error
Causes: 30 sec JAM timer (timing error jam), which sets at the timing when ADF motor is driven, occurs time out.