  • Code: E000-0001
  • Description: Fixing belt temperature rise is insufficient at power ON. Fixing main thermistor (THM1-1) temperature does not reach 50 degrees Celsius within 120 seconds after startup of fixing belt temperature control.
  • Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Replace the fixing belt unit A-2. Faulty drawer connector -> Clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing belt unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB
  • Code: E000-0101
  • Description: Pressure belt temperature rise is insufficient at power ON. Pressure main thermistor (THM2) temperature does not reach 50 degrees Celsius within 250 seconds after startup of pressure belt temperature control.
  • Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the pressure belt main thermistor (to see if the thermistor is disconnected, the harness of the thermistor is disconnected, foreign substance is in the thermistor, failure of the thermistor) -> replace the main thermistor or the pressure stay A-2. Faulty drawer connector is a possible cause -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the AC driver connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-2. Replace the AC driver unit B-3. Replace the DC controller PCB B-4. Replace the fixing unit
  • Code: E001-0001
  • Description: Abnormal temperature rise of fixing main thermistor (circuit failure). Fixing main thermistor (THM1-1) sensed an abnormal high temperature. (ASIC detection)
  • Remedy: 1. Check the detection temperature of the fixing main thermistor in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the fixing main thermistor (THM-1) is caught -> replace the fixing belt unit B. In case that the detection temperature is other than 250 degC B-1. Replace the DC controller PCB
  • Code: E001-0002
  • Description: Abnormal temperature rise of fixing subthermistor 1 (THM1-2) (circuit failure). Fixing subthermistor 1 (THM1-2) sensed an abnormal high temperature. (ASIC detection)
  • Remedy: 1. Check the detection temperature of the fixing sub thermistor 1 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the fixing sub thermistor 1 (THM-2) is caught -> replace the fixing belt unit B. In case that the detection temperature is other than 250 degC B-1. Location of the fixing main thermistor is inappropriate -> replace the fixing belt unit B-2. Replace the DC controller PCB
  • Code: E001-0003
  • Description: Abnormal temperature rise of fixing subthermistor 2 (THM1-3) (circuit failure). Fixing subthermistor 2 (THM1-3) sensed an abnormal high temperature. (ASIC detection)
  • Remedy: 1. Check the detection temperature of the fixing sub thermistor 2 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the fixing sub thermistor 2 (THM-3) is caught -> replace the fixing belt unit B. In case that the detection temperature is other than 250 degC B-1. Location of the fixing main thermistor is inappropriate -> replace the fixing belt unit B-2. Replace the DC controller PCB
  • Code: E001-0011
  • Description: Fixing main thermistor abnormal temperature rise (circuit abnormality). Fixing main thermistor (THM1-1) detected abnormal high temperature. (software detection)
  • Remedy: 1. Check the detection temperature of the fixing main thermistor in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the fixing main thermistor (THM-1) is caught -> replace the fixing belt unit B. In case that the detection temperature is other than 250 degC B-1. Replace the DC controller PCB