Description: POD Deck Air Assist Fan error. [POD Deck Lite] When the Pickup Motor Cooling Fan is not locked
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J30 2. Replace the Motor Cooling Fan (FM4). 3. Replace the Deck Lite Controller PCB.
Code: E905-0003
Description: POD Deck Air Assist Fan error. [POD Deck Lite] When the Pickup Motor Cooling Fan is not unlocked
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J30 2. Replace the Motor Cooling Fan (FM4). 3. Replace the Deck Lite Controller PCB.
Code: E906-0001
Description: POD Deck Air Heater error. [POD Deck Lite] Air Heater high temperature error When 120 deg C or higher temperature is detected for 1 second consecutively
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.
Code: E906-0002
Description: POD Deck Air Heater error. [POD Deck Lite] Air Heater low temperature error When the heater does not become Ready although a specified period of time has passed
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.
Code: E996-xxxx
Description: Timeout error. The DC Controller is not stopped. The Detailed Code varies according to the state transition of the software