Error Codes List page 14
|
|
- Code: 532
- Description: IH coil fan error
The machine does not detect the fan motor lock signal for 2 seconds while the IH coil fan turns on.
- Causes: • Disconnected harness • Overload on the IH coil fan motor • Defective IH coil fan motor • Defective IOB
- Remedy: 1. Check or replace the harness. 2. Replace the IH coil fan. 3. Replace the IOB.
- Code: 533
- Description: IH inverter fan error
The machine does not detect the fan motor lock signal for 2 seconds while the IH inverter fan turns on.
- Causes: • Disconnected harness • Overload on the IH inverter fan motor • Defective IH inverter fan motor • Defective IOB
- Remedy: 1. Check or replace the harness. 2. Replace the IH inverter fan. 3. Replace the IOB.
- Code: 534
- Description: Second duct fan error
The machine does not detect the fan motor lock signal for 2 seconds while the second duct fan turns on.
- Causes: • Disconnected harness • Overload on the second duct fan motor • Defective second duct motor • Defective IOB
- Remedy: 1. Check or replace the harness. 2. Replace the second duct fan. 3. Replace the IOB
- Code: 535
- Description: Paper exit fan error
The machine does not detect the fan motor lock signal for 2 seconds while the paper exit fan turns on.
- Causes: • Disconnected harness • Overload on the paper exit fan motor • Defective paper exit motor • Defective IOB
- Remedy: 1. Check or replace the harness. 2. Replace the paper exit fan. 3. Replace the IOB.
- Code: 536
- Description: Controller fan error
The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
- Causes: • Defective controller fan motor • Disconnected or defective harness • Defective IOB
- Remedy: 1. Replace the controller fan motor. 2. Check or replace the harness. 3. Replace the IOB.
- Code: 540
- Description: Fusing/Paper exit motor error
The IOB does not receive the lock signal 10 seconds after turning on the fusing/ paper exit motor.
- Causes: • Motor overload • Defective fusing/paper exit motor
- Remedy: Replace the fusing/paper exit motor.