PrintCopy.info service

Ricoh MPC3300

Error Codes List page 14

  • Code: 532
  • Description: IH coil fan error
    The machine does not detect the fan motor lock signal for 2 seconds while the IH coil fan turns on.
  • Causes: • Disconnected harness • Overload on the IH coil fan motor • Defective IH coil fan motor • Defective IOB
  • Remedy: 1. Check or replace the harness. 2. Replace the IH coil fan. 3. Replace the IOB.
  • Code: 533
  • Description: IH inverter fan error
    The machine does not detect the fan motor lock signal for 2 seconds while the IH inverter fan turns on.
  • Causes: • Disconnected harness • Overload on the IH inverter fan motor • Defective IH inverter fan motor • Defective IOB
  • Remedy: 1. Check or replace the harness. 2. Replace the IH inverter fan. 3. Replace the IOB.
  • Code: 534
  • Description: Second duct fan error
    The machine does not detect the fan motor lock signal for 2 seconds while the second duct fan turns on.
  • Causes: • Disconnected harness • Overload on the second duct fan motor • Defective second duct motor • Defective IOB
  • Remedy: 1. Check or replace the harness. 2. Replace the second duct fan. 3. Replace the IOB
  • Code: 535
  • Description: Paper exit fan error
    The machine does not detect the fan motor lock signal for 2 seconds while the paper exit fan turns on.
  • Causes: • Disconnected harness • Overload on the paper exit fan motor • Defective paper exit motor • Defective IOB
  • Remedy: 1. Check or replace the harness. 2. Replace the paper exit fan. 3. Replace the IOB.
  • Code: 536
  • Description: Controller fan error
    The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
  • Causes: • Defective controller fan motor • Disconnected or defective harness • Defective IOB
  • Remedy: 1. Replace the controller fan motor. 2. Check or replace the harness. 3. Replace the IOB.
  • Code: 540
  • Description: Fusing/Paper exit motor error
    The IOB does not receive the lock signal 10 seconds after turning on the fusing/ paper exit motor.
  • Causes: • Motor overload • Defective fusing/paper exit motor
  • Remedy: Replace the fusing/paper exit motor.