Description: Heating roller thermopile error The temperature measured by the heating roller thermopile does not reach 0°C for 6 seconds.
Causes: • Loose connection of the heating roller thermopile • Defective heating roller thermopile • Defective thermopile
Remedy: 1. Check if the heating roller thermopile is firmly connected. 2. Replace the heating roller thermopile.
Code: 542
Description: Heating roller warm-up error 1 • After the main switch is turned on or the cover is closed, the increment of the heating roller temperature per 10 seconds is 30°C or less. If this condition is detected five times consecutively, SC 542 is defined. • The heating roller temperature does not reach 100°C for 15 seconds after the heating lamp on. • The heating roller temperature does not reach the ready temperature while 60 seconds after the heating lamp on. • The center temperature of the heating roller does not reach the ready temperature for 30 seconds after the both edge temperature of the heating roller has reached the ready temperature.
Remedy: 1. Check if the heating roller thermistor is firmly connected. 2. Replace the thermistor. 3. Check or replace the thermopile. 4. Replace the heating roller lamp.
Code: 543
Description: Heating roller fusing lamp overheat 1 (software error) The detected fusing temperature stays at 230°C for 1 second.
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.
Code: 544
Description: Heating roller fusing lamp overheat 1 (hardware error) During stand-by mode or a print job, the detected heating roller temperature reaches 250 °C.
Causes: • Defective PSU • Defective IOB • Defective BICU • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.
Code: 545
Description: Heating roller fusing lamp consecutive full power 1 When the fusing unit is not running in the ready condition, the heating roller fusing lamp keeps on full power for 8 seconds.
Causes: • Broken heating roller thermistor
Remedy: Replace the heating roller thermistor.
Code: 547
Description: Zero cross error • The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.