Description: Heat roller abnormally high temperature
Causes: The fusing temperature rises above 240°C.
Code: H4-00
Description: Heat roller abnormally low temperature
Causes: The fusing temperature does not reach 185°C within 27 sec of turning on the power, or the fusing temperature keeps at 140°C.
Code: L1-00
Description: Feeding is not completed within the specified time after starting feeding. (The scan head locking switch is locked)
Causes: The white area and the black marking on the shading plate are used to obtain the difference in the CCD level values for judgment of lock. When the difference in the levels of which and black is small, it is judged that the black mark could not be scanned by lock and the trouble code “L1” is displayed.
Code: L3-00
Description: Return is not completed within the specified time.
Causes: When the mirror base is returned for the specified time (6 sec) in mirror initializing after turning on the power, the mirror home position sensor (MHPS) does not turn ON. Or when the mirror base is returned for the specified time (about 6 sec) after start of copy return, the mirror home position sensor (MHPS) does not turn ON.