PrintCopy.info service

Roland LEC330 VersaUV

Error Codes List page 2

  • Code: 0010
  • Description: Network I/F Initialize has not been completed
  • Causes: Network I/F does not work correctly.
    Firmware for Network I/F is not installed.
  • Remedy: Check if the firmware is installed into Network I/F.
    Main Board replacement
  • Code: 0101
  • Description: Limit Position Initialize in the Service Mode has not been done.
  • Causes: Limit Position Initialize has not been done.
    Limit Position Initialize is ended before it is completed.
  • Remedy: Complete Limit Position Initialize correctly.
  • Code: 0102
  • Description: Head Lock Sensor is ON when it should be OFF, or vice versa.
  • Causes: Head Lock Sensor does not work correctly or is broken.
    Head Carriage is not located at the correct position.
  • Remedy: Head Lock Sensor replacement
    Check the mechanical backlash or loose with the scan axis related parts.
  • Code: 0103
  • Description: Limit Sensor is ON when it should be OFF, or vice versa.
  • Causes: Limit Sensor does not work correctly or is broken.
    Tool Carriage is not located at the correct position.
  • Remedy: Limit Sensor replacement
    Check the mechanical backlash or loose with the scan axis related parts.
  • Code: 0104
  • Description: Capping unit does not work correctly.
  • Causes: Capping Motor does not work correctly or is broken.
    Capping Unit does not work correctly or is broken.
    Capping Sensor does not work correctly or is broken.
    Wiring or Flexible Cable has short circuited or cut-line.
  • Remedy: Capping Motor replacement
    Capping unit replacement
    Capping Sensor replacement
    Flexible Cable replacement
  • Code: 0105
  • Description: Tool Carriage Connection Error
  • Causes: Fault of Tool Carriage Connection
    Loose of Connection Part
    Fault of the Limit Position Initialize value
    Limit Sensor does not work correctly or is broken.
  • Remedy: Check the mechanical Backlash or loose with the Tool
    Carriage part.
    Connection Part Replacement
    Limit Position Initialize