  • Code: 828
  • Description: Self-diagnostic Error: ROM
    The resident read-only memory returned an error during the self-diagnostic test.
  • Causes: - Controller board defective
    - Download controller firmware again
  • Code: 829
  • Description: Self-diagnostic Error: Optional RAM
    The optional RAM returned an error during the self-diagnostic test
  • Causes: - Replace the optional memory board
    - Controller board defective
  • Code: 838
  • Description: Self-diagnostic Error: Clock Generator
    A verify error occurred when setting data was read from the clock generator via the I2C bus
  • Causes: - Replace the controller board
  • Code: 850
  • Description: Network I/F Abnormal
    NIB interface error.
  • Causes: - NIB defective
    - Controller board defective
  • Code: 857
  • Description: USB I/F Error
    USB interface error detected.
  • Causes: - Defective controller
  • Code: 900
  • Description: Electrical total counter error
    The electrical total counter does not work properly.
  • Causes: - NVRAM on the GDI controller board defective