Description: Address exception error (store): Address error in saving process.
Remedy: 1. Check AC power supply and plotter surrounding equipment. 2. Check reappearance by turning ON/OFF the machine power several times. Make sure to perform this check repeatedly even if no problems seem to be present. (Make the same condition as user's.) Contact our customer support center. 3. Check serial number of the plotter. 4. Main board assembly may be defective. • Contact our customer support center. • Replace main board assembly.
Code: E016-06
Display: E 016 error CPU Err [06]
Description: Address exception error (command fetch): Address error in command loading or storing
Remedy: 1. Check AC power supply and plotter surrounding equipment. 2. Check reappearance by turning ON/OFF the machine power several times. Make sure to perform this check repeatedly even if no problems seem to be present. (Make the same condition as user's.) Contact our customer support center. 3. Check serial number of the plotter. 4. Main board assembly may be defective. • Contact our customer support center. • Replace main board assembly.
Code: E016-07
Display: E 016 error CPU Err [07]
Description: Bus exception error (load or store): Bus error in command loading or storing
Remedy: 1. Check serial number of the plotter. 2. Main board assembly may be defective. • Contact our customer support center. • Replace main board assembly.
Code: E016-08
Display: E 016 error CPU Err [08]
Description: System call exception error: Abnormal condition in system call
Remedy: 1. Check serial number of the plotter. 2. Main board assembly may be defective. • Contact our customer support center. • Replace main board assembly.
Code: E016-09
Display: E 016 error CPU Err [09]
Description: Break point exception error: Abnormal condition in break point
Remedy: 1. Check serial number of the plotter. 2. Main board assembly may be defective. • Contact our customer support center. • Replace main board assembly.
Code: E016-10
Display: E 016 error CPU Err [10]
Description: Reserved command exception error: Abnormal condition in reserved command