Description: Y-motor current (Over current error of Y-motor is detected.)
Remedy: 1. Check if there is no error on the print data. (Check if the same error occurs on other data?) 2. Check if it moves to the Y-direction smoothly in the power-off condition. 3. Check if there is no trouble on the timing belt. 4. Check if there is no trouble on the motor cable. (disconnecting, burnout, or the like) 5. Check the FFC between each PCB and shortconnectors connected on the PCB. 6. Replace the Y-axis motor with a new one.
Code: 406
Display: SYSTEM HALT (*) 406 : WIPER ORG
Description: Wiper origin undetectable
Remedy: 1. Execute and confirm [#TEST SENSOR TEST] -> [WIPER-ORG]. (Confirm that the ON/OFF display is switched by moving the wiper back and forth.) 2. Check that the wiper moves back and forth smoothly in manual. 3. Check the assembly and connector connection of wiper origin sensor. 4. Check the connector connection of Y-origin sensor 5. Check the connections between the central-IO PCB and the main PCB, and then disconnect and connect the FFC. 6. Replace the wiper back/forth origin sensor with a new one. 7. Replace the wiper motor with a new one. 8. Replace the FFC located between the central-IO PCB and the main PCB. 9. Replace the central-IO PCB with a new one.
Code: 40b
Display: SYSTEM HALT (*) 40b : UN MAGNETIC
Description: DC motor is driving without excited
Remedy: 1. Update F/W. 2. Upload the parameter and initialize parameter with #PARAMETER. 3. Replace the main PCB with a new one.
Code: 41a
Display: ERROR 41a Z JOG CTRL
Description: Error in controlling of Z-axis Over current error of X-motor is detected.
Remedy:
Code: 449
Display: SYSTEM HALT (*) 449 : SCAN COORD(MIN)
Description: A value exceeding the MIN coordinate value was specified for the Y movement instruction.
Remedy: 1. Restart the machine. 2. Check that the paper width sensor is not skewed. 3. If the error occurs again, upload the parameter or contact the developer.
Code: 44a
Display: SYSTEM HALT (*) 44a : SCAN COORD(MAX)
Description: A value exceeding the MAX coordinate value was specified for the Y movement instruction.
Remedy: 1. Restart the machine. 2. Check that the paper width sensor is not skewed. 3. If the error occurs again, upload the parameter or contact the developer.