PrintCopy.info service

Kyocera ECOSYS M6530cdn

Error Codes List page 2

  • Code: 0150
  • Description: EEPROM read/write error (Main/Engine PWB) 1. No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. 2. Mismatch of reading data from two locations occurs 8 times successively. 3. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: EEPROM (Main/ Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check that the EEPROM is peroperly installed on the Main/Engine PWB and if not, reinstall it. 3. Replace the Main/Engine PWB. 4. Check the EEPROM and if it is damaged, contact the service support.
  • Code: 0160
  • Description: EEPROM data error (Main/ Engine PWB) Reading data from EEPROM is detected abnormal.
  • Remedy: EEPROM (Main/ Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Execute U021 initialize memory. 3. If the EEPROM data are currupted, contact the service support.
  • Code: 0170
  • Description: Billing counting error Mismatch between the value of the Main/Engine PWB and EEPROM, in one of the value of billing counter, life counter, or scanner counter.
  • Remedy: EEPROM (Main/ Engine PWB) 1. Check that the EEPROM installed in the Main/Engine PWB is correct and, if not, install the correct EEPROM for the model. 2. Replace the Main/Engine PWB. 3. If the EEPROM data are currupted, contact the service support.
  • Code: 0180
  • Description: Machine number mismatch When the power is turned on, the machine number does not match the one stored in the Main/Engine PWB.
  • Remedy: EEPROM (Main/ Engine PWB) 1. Check that the EEPROM installed in the Main/Engine PWB is correct and, if not, install the correct EEPROM for the model. 2. Confirm the serial number data for the Main/Engine PWB by using U004. If the mutually different machine number data between "Machine No. (Main)" and "Machine No. (Eng)" is displayed, or if there is a difference between the actual machine number and the number of "Machine No. (Eng)", install the correct EEPROM, and then execute U004.
  • Code: 0190
  • Description: Backup memory device error (Main/Engine PWB) At power up, read/write data from FRAM can not be performed. (retry: 3times)
  • Remedy: FRAM (Main/ Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check that the connectors on the Main/ Engine PWB are properly connected, and if not, re-connect them. 3. Replace the Main/Engine PWB.
  • Code: 0360
  • Description: Communication error between the engine ASIC During the readback data checked after data transmission, the checksum error or the video signal is not inverted. (failed 10 consecutive times)
  • Remedy: Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB Replace the Main/Engine PWB.