  • Code: E024-0000
  • Description: The connector of Developing Assembly Toner Sensor (S25) is disconnected.
    The Developing Assembly Toner Sensor (S25) connection detection signal is absent for 100 msec 10 times in sequence. * Error occurs after the delivery if a paper in passage exists.
  • Remedy: 1. Check connection of the Connector (J2013/J209). 2. Replace the Developing Assembly Toner Sensor (S25). 3. Replace the DC Controller PCB (UN2).
  • Code: E024-0001
  • Description: The Developing Assembly Toner Sensor (S25) is disconnected.
    <At LOW SPEED> The Developing Assembly Toner Sensor (S25) ON counter is checked every 2.5 seconds, and the counter increments 1 count every 25 times when the sensor goes on, and 300 counts are reached. <At HIGH SPEED> The Developing Assembly Toner Sensor (S25) ON counter is checked every 1.5 seconds, and the counter increments 1 count every 15 times when the sensor goes on, and 300 counts are reached.
  • Remedy: 1. Check connection of the Connector (J2013/J209). 2. Replace the Developing Assembly Toner Sensor (S25). 3. Replace the DC Controller PCB (UN2).
  • Code: E025-0000
  • Description: The connector of Sub Hopper Toner Sensor (S26) is disconnected.
    The Sub Hopper Toner Sensor (S26) connection detection signal is absent for 100 msec 10 times in sequence. * Error occurs after the delivery if a paper in passage exists.
  • Remedy: 1. Check connection of the Connector (J2115/J2503/J207). 2. Replace the Sub Hopper Toner Sensor (S26). 3. Replace the DC Controller PCB (UN2).
  • Code: E025-0001
  • Description: Failure of the Bottle Motor (M17)
    When the disconnection status of the bottle motor (M17) is detected 15 times or more continuously with the 100ms cycle during the intermittent rotation When the disconnection status of the bottle motor (M17) is detected 75 times continuously with the 100ms cycle during the continuous rotation * Error occurs after delivering the remaining paper.
  • Remedy: 1. Check connection of the Connector (J2216/J2503/J207). 2. Replace the Bottle Motor (M17). 3. Replace the DC Controller PCB (UN2).
  • Code: E032-0001
  • Description: Failure of NE Controller Counter
    Detection of open circuit of count pulse signal.
  • Remedy: Disconnection of cable.
  • Code: E110-0001
  • Description: Failure of the Polygon Motor (M11)
    The Polygon Motor (M11) speed lock signal does not indicate a locked state a specific period of time after the Polygon Motor (M11) has been started. * The same condition is detected after the error retry is performed.
  • Remedy: 1. Check connection of the Connector (J1/J7/J10/J21/J208/ J8142/J8143). 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB (UN2).