Sharp AL2021

Sunil
Posts: 49
Joined: Mon Feb 01, 2021 1:08 pm

Sharp AL2021

Postby Sunil » Sun Oct 24, 2021 5:52 pm

Sharp AL2021, AL2031, AL2041
Entering the simulation mode
To enter the serviceman simulation mode, press the keys as follows:
[Clear] key → Exposure mode selector key → [Clear] key → Exposure mode selector key

Key rule
[Up], [Down] Key:
    Entry of MAIN CODE/SUB CODE Setting of the adjustment values for the adjustment-related simulations
    When [%] key is pressed simultaneously, the value is displayed in the descending sequence such as [0] → [9], not as [0] → [1].
[START] key:
    Settlement
    <In case of simulations for print> [START] key: Settlement / Print
[Clear] key:
    (Interrupting operation check) Returns to the upper hierarchy.
    On the initial display (00-00), it terminates the simulation.
    Exits from the simulation mode.
    For a simulation of adjustment, the display returns to the initial display (00-00).
Sunil
Posts: 49
Joined: Mon Feb 01, 2021 1:08 pm

Re: Sharp AL2021

Postby Sunil » Sun Oct 24, 2021 5:57 pm

Sharp AL2021, AL2031, AL2041
Simulations:
1 01 Mirror scan operation
[Function]
When [OK]/[START] key is pressed, the home position is checked and the mirror base performs full scan at the speed of the set magnification ratio.
During operation, the set magnification ratio is displayed. The mirror home position sensor status is displayed with the "Drum replacement required lamp ".
(When the mirror is in the home position, the lamp lights up.)
During operation, the copy lamp lights up.
When [Clear] key is pressed, if the operation is on the way, it is terminated and the machine goes to the sub code entry standby mode.
[ZOOM UP/DOWN] key (ZOOM LED ON) or [Fixed magnification ratio select] key (Fixed magnification ratio LED ON)
∗ When [ZOOM UP/DOWN] key is pressed, the magnification ratio is displayed for a certain period, and the display returns to the sub code display.
∗ When [%] key is being pressed, the magnification ratio can be displayed.

1 02 Mirror home position sensor (MHPS) status display
[Function]
Monitors the mirror home position sensor, and makes the "Drum replacement required lamp" turn on during the sensor ON status.

1 06 Aging of mirror scanning
[Function]
When [START] key is pressed, the mirror base performs full scan at the speed of the set magnification ratio.
During operation, the set magnification ratio is displayed. After 3sec, the mirror base performs full scan again.
∗ When [START] key is pressed once, the ready lamp remains OFF.
The mirror home position sensor status is displayed on the "Drum replacement required lamp." (The lamp is ON when the mirror is in the home position.) During aging, the copy lamp is ON.
[Operation]
The operation is similar to simulation 1-01.